化粪池的设置还应符合下列规定: The setting of septic tank shall also meet the following requirements: 1、化粪池宜设置在接户管的下游端,便于机动车清掏的位置。 1. The septic tank should be set at the downstream end of the household connecting pipe, so as to facilitate the cleaning of motor vehicles. 3、化粪池应设置通气管。 3. The septic tank shall be equipped with vent pipe. 4、化粪池的池壁和底板应防止渗漏。 4. The tank wall and bottom plate of the septic tank shall prevent leakage. 6、化粪池的检修口应采用密闭双层井盖。 6. The manhole of the septic tank shall be sealed with double-layer well cover. 7、化粪池宜采用防渗钢筋混凝土工法。 7. The septic tank should adopt the anti-seepage reinforced concrete construction method. 8、当受条件限制化粪池设置于建筑物内时,应采取通气、防臭和防爆措施。 8. When the septic tank is set in the building due to restrictions, ventilation, deodorization and explosion-proof measures shall be taken. 9、当采用成品化粪池时应有产品质量认证,且寿命应与建筑物的设计寿命相当。当不能满足时应有可靠的更新和改造措施。 9. When the finished septic tank is used, the product quality certification shall be provided, and the service life shall be equivalent to the design life of the building. When it can not meet the requirements, reliable renewal and transformation measures shall be taken. |